SEW-EURODRIVE USA

Login
You are here: Home > Documentation \ Software \ CAD > Software Result
Software
Search Filter:
Product
Software Category
 
 
Hotfix2 for MOVI-C® CONTROLLER UHX25A (firmware)  

For: MOVISUITE®, MOVI-C® Controller, MOVIKIT®, MOVIRUN®,

version: V3.02
Hotfix2 for MOVI-C CONTROLLER® advanced (UHX25A) (MOVISUITE® V2.1 (system package 10)) remedies the following problem:
The engineering connection concerning visualization connection, programming system, and socket communication of the application can be disrupted (limited robustness). Affected are engineering port X80 of UHX25A; Not affected are communication connections on SBus plus/EtherCat.
Hotfix2 significantly increases the robustness of the (described ) socket communication.
 
Installation Notes
Release Notes

15,85 MB
to top
 
Hotfix2 for MOVI-C® CONTROLLER UHX45A (firmware)  

For: MOVISUITE®, MOVI-C® Controller, MOVIKIT®, MOVIRUN®,

version: V3.02
Hotfix2 for MOVI-C CONTROLLER® advanced (UHX45A) (MOVISUITE® V2.1 (system package 10)) remedies the following problem:
The engineering connection concerning visualization connection, programming system, and socket communication of the application can be disrupted (limited robustness). Affected are engineering ports X80 and X81 of UHX45A; Not affected are communication connections on SBus plus/EtherCat.
Hotfix2 significantly increases the robustness of the (described ) socket communication.
 
Installation Notes

15,90 MB
to top
 
Hotfix2 for MOVI-C® CONTROLLER UHX65A (firmware)  

For: MOVISUITE®, MOVIKIT®, MOVIRUN®,

version: V3.02
Hotfix2 for MOVI-C CONTROLLER® progressive (UHX65A) (MOVISUITE® V2.1 (system package 10)) remedies the following problem:
The engineering connection concerning visualization connection, programming system, and socket communication of the application can be disrupted (limited robustness). Affected are engineering ports X80 and X81 of UHX65A; Not affected are communication connections on SBus plus/EtherCat.
Hotfix2 significantly increases the robustness of the (described ) socket communication.
 
Installation Notes

19,43 MB
to top
 
Hotfix3 for MOVI-C® CONTROLLER (firmware)  

For: MOVISUITE®, MOVI-C® Controller, MOVIKIT®, MOVIRUN®,

version: V3.03 (UHX25A, UHX45A, UHX65A) bzw. V4.03 (UHX85A)
The patch for hotfix3 includes firmware for all MOVI-C® CONTROLLER (UHX25A, UHX45A, UHX65A, UHX84/85A) and is solely intended for MOVISUITE® V2.2.
The patch for MOVI-C® CONTROLLER hotfix3 for MOVISUITE V2.2 remedies the following problems:
- Controller bugfix (hotfix1 + hotfix2)
– Startup timeout time for EtherCAT® master too short (until now 1 s, problem primarily together with UHX65A)
– Visualization connection to UHX25A and UHX45A cannot read  symbolic variables
– IEC parameter master (IEC application) blocks after some time
– Safety routing with basic FSoE routing does not work among others when using double axes
– Stabilization of SEW engineering communication
 
Installation Notes
Release Notes

110,92 MB